325/328 Excavator
Operation and Maintenance Manual 62
AIR CLEANER
See the SERVICE SCHEDULE for the correct service
interval. (See SERVICE SCHEDULE on Page 59.)
Daily Check
Figure PM-5
Check the condition indicator (Item 1) [Figure PM-5]. If
the red ring shows in the condition indicator, the filter
needs to be replaced.
Replace the inner filter every third time the outer filter is
replaced or as indicated.
Replacing The Filters
Outer Filter
Release the two fasteners (Item 2) [Figure PM-5].
Remove and clean the dust cup (Item 3) [Figure PM-5].
P-49412
1
2
3